  查找剩余電流動(dòng)作中間繼電器自身故障。先切斷電源,再將剩余電流動(dòng)作中間繼電器的零序互感器負(fù)荷側(cè)引線全部拆除再合中間繼電器。若中間繼電器仍然無(wú)法投運(yùn),則說(shuō)明中間繼電器自身故障,應(yīng)予以修理或更換。
  Find the fault of residual current action intermediate relay itself. First cut off the power supply, and then remove all the lead wires on the load side of the zero-sequence transformer of the remaining current action intermediate relay before closing the intermediate relay. If the intermediate relay still cannot be put into operation, it indicates that the intermediate relay itself is faulty and should be repaired or replaced.
  若能正常運(yùn)行,則中間繼電器本身并無(wú)故障,再查找配電盤或者線路。先將各路出線或交流接觸器負(fù)荷切斷,若不能運(yùn)行則說(shuō)明配電盤上有故障,應(yīng)檢查各路電氣、儀表等設(shè)備是否絕緣良好,接線是否正確;若能正常運(yùn)行則說(shuō)明配電盤上無(wú)故障。當(dāng)確認(rèn)故障發(fā)生在外線路上時(shí),可采用分線查找法查找故障點(diǎn)。
  If it works normally, there is no fault in the intermediate relay itself, and then look for the distribution board or line. First cut off each outlet line or ac contactor load, if it can not run, it means there is a fault on the distribution board, should check each electrical, instrument and other equipment is good insulation, wiring is correct; If it works normally, there is no fault on the distribution board. If a fault occurs on an external line, use the split line search method to locate the fault.
  直觀巡查法就是巡視人員針對(duì)故障現(xiàn)象進(jìn)行分析判斷,對(duì)保護(hù)區(qū)域包括剩余電流動(dòng)作中間繼電器和被保護(hù)的線路設(shè)備等進(jìn)行直觀巡視,從而找出故障點(diǎn)。
  Intuitive inspection method is patrol personnel for fault phenomenon analysis and judgment, the protection area including residual current action intermediate relay and protected line equipment intuitive inspection, so as to find the fault point.
  ABB中間繼電器價(jià)格人員認(rèn)為巡視時(shí)應(yīng)著重對(duì)線路的轉(zhuǎn)角、分支、交叉跨越等復(fù)雜地段和故障易發(fā)點(diǎn)進(jìn)行檢查。這種方法簡(jiǎn)便易行,適用于對(duì)明顯故障點(diǎn)的查找。如導(dǎo)線斷線落地、拉線與導(dǎo)線接觸及錯(cuò)誤接線等。
  ABB intermediate relay price personnel believe that inspection should focus on the line corner, branch, crossing and other complex sections and fault prone points. This method is easy to use and is suitable for the search of obvious fault points. Such as wire broken ground, pull wire and wire contact and wrong wiring, etc.
  排查線路故障點(diǎn)時(shí),斷開(kāi)低壓電網(wǎng)的各條分支線路,僅對(duì)主干線進(jìn)行試送電,若主干線無(wú)故障,那么主干線便能正常運(yùn)行。然后,再依次將分支和末端投入運(yùn)行。哪條線路投入運(yùn)行時(shí)中間繼電器跳閘,故障點(diǎn)就在哪條線路上,就可在此線路上集中查找故障點(diǎn)。
  When identifying the fault point of the line, disconnect each branch line of the low-voltage power grid, and only test the main line. If the main line has no fault, then the main line can run normally. The branches and ends are then put into operation. When the intermediate relay trips when the line is put into operation, the fault point is on the line, and the fault point can be searched centrally on this line.
  中間繼電器跳閘有什么解決辦法?以上就是幾個(gè)解決方法,如果您還有其他方面的方法可以來(lái)網(wǎng)站www.xzthjc.com來(lái)我們分享交流。
  What is the solution to intermediate relay trip? The above is a few solutions, if you have other aspects of the method can come to the website www.xzthjc.com to share with us.


地址:濟(jì)南市槐蔭區(qū)經(jīng)四緯十二盧浮商務(wù)中心D2-909   電話:0531-87066186
網(wǎng)站:http://www.xzthjc.com/   備案號(hào):魯ICP備2021012001號(hào)-1  

魯公網(wǎng)安備 37010402001012號(hào)