正因?yàn)殚_關(guān)電器有觸點(diǎn),使其轉(zhuǎn)換深度較高,因此在接通電路時(shí),開關(guān)電器執(zhí)行電流的電能損耗較小,對(duì)被控電路的影響較小。
Because of the contact point of the switch, the switch has a higher conversion depth, so when the circuit is switched on, the power loss of the switching current is smaller, and the impact on the controlled circuit is smaller.
切斷電路時(shí),開關(guān)電器有觸點(diǎn),它的執(zhí)行電路 ide電阻很高,因此可以保證電器的電壓等級(jí)。
When the circuit is cut off, the switching appliance has contacts, and the ide resistance of its execution circuit is very high, so the voltage level of the appliance can be guaranteed.

與此相反,無(wú)觸點(diǎn)電器啟動(dòng)后不會(huì)產(chǎn)生電弧。但是非接觸式電器轉(zhuǎn)換深度較低,所以其損耗較大,并且發(fā)熱比較嚴(yán)重。
In contrast, contactless appliances do not generate arcing after starting. But the non-contact electrical appliances conversion depth is low, so its loss is large, and heating is more serious.
繼電器激磁線圈通電后,激磁線環(huán)電流在電磁系統(tǒng)中逐漸增大并產(chǎn)生磁通,其中銜鐵與鐵心間氣隙的磁通對(duì)銜鐵起作用。
After the relay exciting coil is energized, the exciting loop current increases gradually in the electromagnetic system and produces magnetic flux, in which the flux between armature and air gap between armature and core acts on armature.
當(dāng)工作磁通逐漸增大時(shí),作用于銜鐵的電磁吸力(轉(zhuǎn)矩)也越來(lái)越大。如果電磁吸力大于系統(tǒng)反力,銜鐵將繞其轉(zhuǎn)動(dòng)軸旋轉(zhuǎn),帶動(dòng)執(zhí)行部分C0的動(dòng)觸頭運(yùn)動(dòng)(觸頭系統(tǒng)),從而實(shí)現(xiàn)常開觸頭和常閉觸頭變位。
When the working magnetic flux increases gradually, the electromagnetic force (Torque) acting on the armature also increases. If the electromagnetic force is greater than the system reaction force, the armature will rotate around its rotating axis and drive the moving contact (contact system) of the actuating part C0, thus realizing the constant open contact and constant close contact displacement.
當(dāng)激磁線圈斷電后,激磁線圈的電流逐漸減小,電磁系統(tǒng)的磁通也逐漸減小,工作氣隙磁通也隨之減小,作用在磁鐵上的電磁吸力越來(lái)越小。如果電磁吸力小于磁鐵反力,
ABB接觸器則銜鐵在系統(tǒng)反力的作用下,開始返回初始位置,帶動(dòng)動(dòng)觸點(diǎn)C0向初始位置移動(dòng),直至常開觸點(diǎn)及常閉觸頭復(fù)位。如果電磁吸力小于磁鐵反力,則銜鐵在系統(tǒng)反力的作用下,開始返回初始位置,帶動(dòng)動(dòng)觸點(diǎn)C0向初始位置移動(dòng),直至常開觸點(diǎn)及常閉觸頭復(fù)位。
When the power of the exciting coil is cut off, the current of the exciting coil decreases, the magnetic flux of the electromagnetic system decreases, the air gap magnetic flux also decreases, and the electromagnetic force acting on the magnet decreases. If the electromagnetic force is less than the reaction force of the magnet, the armature of the ABB contactor begins to return to the initial position under the reaction force of the system, driving the contact C0 to move to the initial position until the normally open contact and normally closed contact are reset. If the electromagnetic force is less than the reaction force of the magnet, the armature begins to return to the initial position under the reaction force of the system, and drives the contact C0 to move to the initial position until the normally open contact and normally closed contact are reset.