菲尼克斯端子接線有什么留意事項
1、擰緊力要適中。避免用力過大來松開螺栓和螺母。如果發現螺栓和螺母有松動,請立即更換,不要湊合工作。
1, tightening force should be moderate. Avoid using too much force to loosen bolts and nuts. If the bolts and nuts are found to be loose, please replace them immediately, do not work at all.
2、用螺絲刀擰緊或松開螺母時,一定要用螺絲刀用力擰緊螺絲,然后再擰緊或松開,以免螺絲刀與螺絲跑偏,造成螺絲損壞,不易拆卸,特別是在吊箱。
2. When tightening or loosening the nut with a screwdriver, the screwdriver must be used to tighten the screw forcibly, and then tighten or loosen the screw, so as to avoid deviation between the screwdriver and the screw, resulting in screw damage and difficult to disassemble, especially in the hanging box.
3、如發現螺栓、螺母難拆裝,不必魯莽行事,以免變形難拆裝,應提供適度敲擊,或加螺絲松動劑、稀硫酸等拆裝前。
3, if it is found that bolts and nuts are difficult to disassemble, do not act rashly, so as not to disassemble deformation, should provide moderate percussion, or add screw loosening agent, dilute sulfuric acid and other disassembly before.
4、不要用虎鉗擰緊或松開螺栓和螺母,以防損壞。使用活動扳手時,應調整開口,以免螺栓、螺母損壞變形,造成拆卸困難。
4. Do not tighten or loosen bolts and nuts with a vise to avoid damage. When using an adjustable wrench, adjust the opening to avoid damage and deformation of bolts and nuts, which may cause difficult removal.
5、同一個
菲尼克斯端子允許連接兩根以上同類型、同規格的電線。
5. The same Phoenix terminal is allowed to connect more than two wires of the same type and specification.
6、對于容易松動或接觸不良的接線端子,必須用“?”將接線器緊固在接線端子上。類型以增加總接觸面積并避免松動。
6, for easy to loose or poor contact terminal, must use "?" Fasten the connector to the terminal block. Type to increase the total contact area and avoid loosening.

7、線接頭或線頭相互連接時,禁止修改中間的非銅或低導電性墊片。
7. When wire joints or wire ends are connected to each other, it is forbidden to modify the non-copper or low conductivity gasket in the middle.
8、連接線材連接器時,規定接觸區域清潔,無空氣氧化。接線鼻或銅排連接時,接觸表面后可將導電膏擦拭干凈,然后擰緊。
8. When connecting the wire connector, the contact area shall be clean without air oxidation. When connecting the wiring nose or copper bar, wipe the conductive paste clean after touching the surface, and then tighten it.
9、連接臨時線時,應將單線銅線的規定端子對折一次,然后接到空氣開關的下孔;單芯硬線應收在“?”鍵入空氣開關的下孔。
9, when connecting the temporary line, the specified terminal of the single wire copper wire should be folded in half once, and then connected to the lower hole of the air switch; Single core hard wire receivable in "?" Type the lower hole of the air switch.
10、30KW及以上電機的接線,規定電機組出線與電機連接電纜之間不允許使用導電性差的跳線墊圈,如熱鍍鋅螺母、扁墊圈、扭簧墊圈等。
10. For the wiring of 30KW and above motors, it is stipulated that jumper washers with poor conductivity are not allowed to be used between the outlet line of the generator set and the connecting cable of the motor, such as hot-dip galvanized nuts, flat washers, torsion spring washers, etc.
11、當用絕緣膠帶纏繞電纜或其他機械設備以保持絕緣層時,電纜護套應按壓力位置的1/2比例從一端到另一端纏繞,至少繞一圈。
11. When wrapping cables or other mechanical equipment with insulating tape to maintain the insulation layer, the cable sheath should be wound from one end to the other at least once in proportion to the pressure position.